What it does
Isolated Footing designs a square pad footing under a column to ACI 318-14 and NSCP 2015. Enter the service and factored column loads, column size, materials and allowable soil bearing; it sizes the plan dimension from the net bearing pressure, finds the thickness required for punching shear and one-way shear, and designs the bottom steel and its spacing.
- Net allowable bearing pressure after footing and soil weight
- Plan dimension B of the square footing
- Thickness required for two-way (punching) shear and one-way shear
- Flexural steel, minimum steel and bar spacing
- Eccentric columns, with partial-bearing checks
- A given footing can be analysed instead of designed
How it works
The net allowable pressure is the gross allowable pressure less the weight of the footing and of the soil above it, so it depends on the footing thickness. The calculator iterates the thickness and the plan size to a fixed point (or does a single approximate pass if you choose that option).
The plan dimension follows from the service load: B² = P / q_net. The soil pressure for the structural design is the factored load over the area, qu = Pu / B². The footing depth is then taken as the larger of the depths needed for punching shear around the column (critical perimeter at d/2 from the column face, ACI 318-14 §22.6) and one-way beam shear (§22.5).
Flexure is designed at the column face for the cantilever projection of the footing, with the minimum steel for footings and the spacing limits applied. Bars are reported as a count, diameter and spacing in each direction.
Worked example
Square footing for a 400 mm column
Given
- Service load P = 900 kN, factored load Pu = 1 260 kN, column 400 × 400 mm (interior)
- f′c = 28 MPa, fy = 420 MPa, 20 mm bars, 75 mm cover
- Gross allowable bearing 200 kPa, soil 18 kN/m³, concrete 24 kN/m³, footing base 1.5 m below grade
Solution
- Net pressure for a 425 mm footing: q_net = 200 − 24 × 0.425 − 18 × (1.5 − 0.425) = 170.45 kPa
- Required area: A = P / q_net = 900 / 170.45 = 5.28 m², so B = 2.30 m (rounded up from 2.298 m)
- Factored soil pressure: qu = Pu / B² = 1 260 / 2.30² = 238.2 kPa
- Governing depth: punching shear requires d ≈ 308 mm, one-way shear d ≈ 248 mm, so punching governs
- Total thickness rounded to 425 mm; flexure needs 2 607 mm² of steel per direction, giving 9 ⌀20 mm bars at about 266 mm
Result
B = 2.30 m, thickness 425 mm, qu = 238.2 kPa, 9 ⌀20 mm bars each way. The net pressure, area and factored pressure are hand-checkable; the depths and steel are the calculator’s output.
Frequently asked questions
How do you size an isolated footing?
Divide the service column load by the net allowable soil pressure to get the required plan area, then take the square root for a square footing. The net pressure is the gross allowable pressure minus the weight of the footing and the soil above it. The thickness is then set by punching shear and one-way shear, and the steel by flexure at the column face.
What is the net allowable bearing pressure?
It is the gross allowable bearing pressure less the pressure from the footing’s own weight, the soil backfill above it and any surcharge. Only the remainder is available to carry the column load, which is why a deeper footing needs a larger plan area for the same load.
Where is the critical section for punching shear in a footing?
At a perimeter d/2 from the face of the column, where d is the effective depth of the footing (ACI 318-14 §22.6.4.1). The factored shear on this perimeter is the column load less the soil pressure acting inside it, and it is compared with the two-way shear capacity Vc, which depends on the column shape and position.
Which design code does the calculator follow?
ACI 318-14 as adopted by NSCP 2015, for shear, flexure, minimum steel and development. Each result row in the worked solution names the clause it comes from.
Can it design a footing for an eccentric column?
Yes. The footing can be checked with the column offset from its centre; the bearing state is reported as full, partial in one direction or partial in both, and the pressure is recomputed accordingly.
References
- ACI 318-14 §13.3, shallow foundations; §22.6, two-way shear; §22.5, one-way shear
- NSCP 2015 Chapter 4, Structural Concrete
- Wight & MacGregor, Reinforced Concrete: Mechanics and Design, footing design