3D Model Space — ZetaStruct

The full workflow in one page: build a 3D frame, load it, analyse it, design every member, and print the drawings and reports. This is an interactive tool for signed-in members (Pro and Max plans), so its working screens are not readable without an account; the description below is the public documentation for it.

Basis: NSCP 2015 (§203 combinations, §207 wind, §208 seismic, §409/§424 RC), ACI 318-14, AISC 360-16, NDS for timber.

Tab ribbon

The full-width row under the header, in three labelled groups plus two utilities. The groups are the sequence — MODEL builds the frame, ANALYSE solves it, RESULTS is where the design and the drawings are read — and each needs the one before it. Display and Projects sit past the divider on the right because they are neither: one changes how the model is drawn, the other opens a different model, and both apply at whatever stage you are at.

Viewport

The 3D scene, with the model's name and its autosave badge in the top-left corner and the selection chip under them. Orbit by dragging, pan with Shift+drag, zoom with the scroll wheel. Clicking a member or slab selects it and opens its detail panel. What the scene DRAWS is set on the Display tab, not here.

Display

The overlays the viewport draws. Its own tab, past the divider on the right of the ribbon because it is not a step in the sequence — and the toggles stay on whatever tab you switch to afterwards, because what the 3D view is drawing is not a property of which tab is open. Each toggle carries its own colour key, and says what it is waiting for when it has nothing to draw yet.

Geometry tab

Builds and edits the model. The parametric models list is the fastest start (column grid, towers, masts, racks, sheds, signs — each in its usual material); everything can then be edited node by node.

Selection panel

Whatever is selected in the 3D view, at the top of the control panel and on every tab. For a member: role, length, section, the design verdict with its utilisation, the governing forces, and the six force diagrams behind a disclosure. For a slab: panel size, its area loads and the tributary split. It used to live at the foot of the Analysis tab, so clicking a member gave you a chip on the canvas and nothing else unless you were on that one tab.

Selected-member overrides

Appears in the Geometry tab when a member is selected. These are per-member overrides — each one is optional and blank means "use the model default".

Properties tab

Materials and section sizes. The frame material chosen here decides which design path every member takes.

Supports tab

Soil data for the footing design that runs as part of Design all.

Loading tab

Everything applied to the model. Loads are categorised (D, L, Lr, W, E, T…) and the NSCP combinations are then applied as data over a single factorisation.

Analysis tab

Solver options, then the results. Options change the stiffness the solver assembles, so re-run Analyze after changing any of them.

Modal tab

Free-vibration properties and linear dynamic response.

Pushover tab

Nonlinear static capacity curve with plastic hinges.

Pushover tab — biaxial (skew) pushover

A second pushover on the same tab, and a different idealisation. The one above reduces the building to an equivalent plane frame and gives each member end a hinge that bends about ONE axis. This one runs on the real 3-D model with no reduction, and each hinge carries a moment vector whose two bending axes yield on a single coupled surface. That is what makes a push at an arbitrary plan angle meaningful: at 45° a corner column can sit at 0.8·Mpy AND 0.8·Mpz, which two independent 1-D hinges would call elastic and the real section calls well past yield.

Nonlinear tab

Nonlinear time history. Two plasticity models are offered; they differ in how the structure is idealised, not just in numerics.

Design tab

Runs the design pipeline and shows every schedule. Rows expand to a full worked solution with drawings.

Finite-element check of joints and column bases (CBFEM, Max plan)

After a design run, the card under the steel connection schedule rebuilds each designed steel joint (a W beam or girder on a W column, shear tab or moment connection, with any brace landing on a corner gusset: an HSS slotted over it, or an angle, channel or tee bolted on it; and braces meeting a beam away from any column, a chevron, on one gusset under it), each designed bolted splice of two members end to end (wide flanges by flange and web plates, with fillers where the two differ in depth; rectangular or round tubes by two bolted flange plates; at a ridge or knee the members are cut on the bisecting plane and the plates kinked there, or lie on it), each open node of the connection ledger as a directly welded node (every member CJP-welded onto the member running through the node: the FE's own detail, marked FE checked only, never designed) and each designed column base as a plate, bolt and weld model, and solves it under the few load combinations that load it most. Plates are layered shell elements with an elastic-plastic steel at φ·Fy (φ = 0.90); bolts and anchor rods are springs checked against AISC 360-16 §J3.6–J3.7; welds are ties checked on the force they carry (§J2.4); contact carries compression only; a base plate bears on a compression-only foundation and its rods are checked in the concrete per ACI 318-14 Chapter 17 under the FE rod forces. A plate fails at a 5 % plastic strain, read as the mean over a 30 mm radius (the EN 1993-1-5 Annex C convention). Where the designed detail of a joint, splice or base has been run, its FE verdict governs that joint in the schedules, the design summary and the report, with the hand calc printed beside it; joints not run keep the hand calc. NSCP 2015 and AISC 360-16 do not prescribe FE connection design, so the engineer of record decides whether to rely on it.

Plans tab

Drawing sheets generated from the model and the completed design.